Home / Capabilities / Testing

Testing

Two questions decide what a buyer trusts: what was measured on every metre, and what the document actually states.

On every metre

PropertyMethodResolutionRecorded
DiameterIn-line laser micrometer0.001 mmRecorded against the spool
SurfaceEddy currentFull lengthRejects flagged before packing
ContinuityResistance checkPer spoolShort or open found before shipment

Once per lot

PropertyMethodApplies toIncluded
EMFAgainst the reference tableThermocouple gradesOn request
ResistivityFour-terminalThermocouple and resistance wireStandard
Tensile and elongationPer leg or per gradeAllStandard
CompositionMelt analysisAllStandard on 3.1
Cladding ratioCross-section and conductivityCopper-clad steelStandard

Documents

Records

Results are retained by batch number. A question about a delivery from months earlier is answered from the measurement taken at the time, rather than by re-testing a sample that may no longer represent the lot.